PowerVM VIOS for IBM i

 

In this post, I will discuss the pros and cons of creating a completely virtualized IBM i environment with redundant VIOS (Virtual I/O Server).  You can just look at the name of this website to understand where I stand on that issue.  Many IBM i administrators try to avoid VIOS for several reasons.  To be completely honest, a LONG time ago I was even one of them.  That was a mistake.  I want to make the case for why you should consider VIOS for I/O virtualization on your next system.

In the present day, there are many options for virtualizing the workload on an IBM Power server.  The options range from absolutely no virtualization (a non-partitioned system), to all Input/Output and processor completely virtualized and mobile.  According to the 2022 Fortra (formerly HelpSystems) survey, 22% of you have a single partition, and 25% have two partitions.  If that’s you, you probably don’t need VIOS... yet. 

It is also common to find particularly critical partitions with dedicated processors and dedicated I/O resources on the same Power servers as fully virtualized partitions that are sharing resources. 

I’m a big fan of virtualizing everything, but I understand that is not always optimal.  Fortunately, PowerVM has the flexibility provide the right choice for you on a partition-by-partition basis.

Why should you virtualize I/O? 

Ask yourself a question:  If you have more than one partition, why don’t you buy a separate Power system for each partition? 

Your business probably requires multiple partitions for a reason: workload splitting, different applications, development/testing environments, etc.  You also have good reasons to consolidate your separate workloads onto a smaller number of more powerful systems.  Usually, those reasons relate to things like cost, allowance for growth, limited floor space, power, or cooling requirements.

The same reasons apply to why you should virtualize your I/O resources.  Ethernet infrastructure (especially 10G) is a limited resource.  Switches, cabling and SFPs all add to expenses and complexity.

Sharing fiber channel ports for storage also reduces the number of ports needed on SAN switches, as well as reducing cable needs.  This saves money and time.

If you use external (SAN) storage, you can even use Live Partition Mobility (LPM) to move running partitions between physical servers.  This is a very common practice in the AIX world, but fairly rare for IBM i.  More to come on that.

External Storage also allows you to leverage technologies such as FlashCopy to create backups with almost zero downtime or create test or reporting copies practically instantly.  It will also greatly simplify server migrations and enable storage-based replication for High Availability and Disaster Recovery solutions.  I’ll write a future article that delves deeper into the benefits of external storage, as it is a technology that deserves a deep dive.

When you have a fully virtualized PowerVM infrastructure in place, creating a new partition becomes a very simple thing.  There is no longer any need to assign any physical resources.  Just create new virtual resources with the HMC GUI and your partition (IBM i, AIX, or Linux) is ready to go.  Okay, you might need to do some zoning and maybe assign some storage before you can use it, but the partition will be ready to go.

Redundancy is critical

Proper virtualization leverages redundancy to improve reliability.  Ideally, all your virtualized resources should have backup. 

Virtual Ethernet connections should be based on vNIC with multiple backing adapters for automatic failover, or Shared Ethernet Adapters backed by multiple physical adapters in multiple VIOS.  Each adapter should connect to the network via separate network switches.  Eliminate all single points of failure and you will eliminate many potential problems before they happen.

Storage should have multiple paths via multiple fiber channel cards owned by multiple VIOS partitions connected through multiple SAN switches (fabrics) to multiple storage ports.  Again, eliminate those single points of failure.

A properly implemented virtual infrastructure is more reliable than individual physical adapters directly mapped to partitions.

Don’t fear the VIOS

If I had any musical talent, I’d make a version of the classic “Don’t Fear the Reaper” song as “Don’t Fear the VIOS”.  I don’t, so I’ll just stick with text.  Trust me.  It’s better this way.

Many IBM i administrators want to avoid VIOS because it is based on AIX, which is an unfamiliar technology.  As I mentioned before, I was one of those until I spent a few years at a company which used VIOS extensively.

Let me be very clear about this.  AIX guys are NOT smarter than IBM i guys.  They just understand a different command syntax.  They might be smarter than Windows guys, but who isn’t, right?

AIX users should NOT be the only ones that benefit from VIOS in their environments.  VIOS is intended to be implemented as an appliance, similar to the HMC, but exclusively in software.  There is a connection to the HMC that is the primary means of configuration.  There is also a command line environment that is subset of simplified AIX commands and some commands that are specific to VIOS.  It is well documented with both online help and manuals, but you will rarely need to use it.

The fact is, once you have done the basic install of VIOS, all your ongoing monitoring and configuration can be completed from the modern Enhanced HMC GUI interface.  If you want to add a partition, map a new fiber channel port , configure a new vNIC, etc. You do it all with clicks on a web interface.  The only time you MUST use the command line on the VIOS is for a few commands during an install, and to install software updates.  Software updates are usually a painless process that involves an install to an alternate boot disk and a simple reboot to activate.  The alternate disk install also means the upgrades are completely reversible in case of problems.  Remember that you want to have redundant connections to multiple VIOS, so that reboot will not be disruptive to your environment. 

I should mention that just because you usually don’t have to use the command line interface doesn’t mean you won’t want to use the command line interface.  There is a massive amount of information to be had from those simple commands.  Watch for a future post where I publish and explain some of my favorite information gathering VIOS commands.

The benefits of VIOS outweigh the costs, especially if you are using external storage.

Licensing topics

Fun fact, you are probably already licensed for VIOS.  PowerVM is required for partitioning, and all editions include VIOS.  If have PowerVM licenses for your server, you are already entitled to install VIOS.  You can get it from IBM Entitled System Support by going to “My Entitled Software”, “By Product” and select 5765-VE3. 

Another important consideration for those of you with extra processors not licensed for IBM i, VIOS is not IBM i, so you do not need those licenses for the processors running VIOS.  That means the processor overhead related to handling the I/O virtualization does not have a premium beyond the cost to activate the processor.  You can make sure you are in compliance by using HMC processor pools to limit the IBM i partitions to the number of licensed processors, and putting your VIOS (and Linux) in an uncapped pool.

Another virtualization topic specific to IBM i is the way the O/S and most applications are licensed.  I mentioned earlier that Live Partition Mobility, moving a running partition to a different server, is a common practice for AIX shops.  It is pretty rare for IBM i.  I think one of the key reasons that has been true historically is that AIX O/S and applications are not generally licensed to a processor while IBM i O/S and applications are pretty much always licensed to a processor serial number.  That means moving an active IBM i partition to another Power server can result in license problems.  Fortunately, IBM recently announced Virtual Serial Numbers that can be attached to a partition and migrate with it.  If Live Partition Mobility appeals to you, look into getting a Virtual Serial Number. 

I should mention that since LPM moves memory over a network to the other server, LPM on IBM i may require a much more robust network environment than the equivalent AIX resources.  IBM i uses single level storage, so it uses large amounts of very active memory.  There are certainly memory size and activity limits that could preclude the use of LPM for very large environments.  As always, your environment matters, and your results may vary.

 

iVirtualization (AKA i hosting i)

There is another option for virtualizing I/O and disk resources for a client partition by using the iVirtualization functionality built into IBM i since V6.1.  This functionality allows you to virtualize ethernet adapters owned by the parent partition and to create virtual disk objects that are shared to another client partition as virtual SCSI disks.

The *NWS* commands to support this are all native IBM commands that will look familiar to IBM i administrators.  Don’t kid yourself.  They are no less complex than the corresponding VIOS commands to someone that has never used them.

In some limited situations, iVirtualization might be a viable option.  For example, on a small system with internal NVMe on a single backplane such that it is not possible to split between multiple VIOS for redundancy. 

Another case where iVirtualization might be preferred is for a small linux test partition hosted from an existing IBM i partition with internal disk and no VIOS infrastructure.

I would not use it with external storage in any case as it would lose all of the benefit of multipathing.

Now here are the primary reasons I would recommend VIOS over iVirtualization:

-          License costs.  Hosting on IBM i means paying for an IBM i license for work that could be free.

-          Performance.  The numbers I have seen have consistently shown the client partitions do not perform as well as an equivalent VIOS configuration.  This is especially problematic with an IBM i client as performance is related to number of disks, which results in more objects and more overhead.

-          Completely manual configuration.  The HMC GUI configuration that is available with VIOS does not work with iVirtualization, so it needs to be configured completely with commands.

-          No Redundancy.  When the host is down, the clients are down. To be fair, you could use multiple host partitions and mirror disks in the client, but you can do that with VIOS also.

-          No LPM.  Live Partition Mobility is not supported for clients of iVirtualization.

-          No development.  If you look at the table of changes in the IBM i Virtualization Summary referenced below, you will see that there has been only one change to iVirtualization since 2015, compared to constant development and improvements for VIOS.

 

What if you need help implementing VIOS with IBM i?

Whether you have a large environment or small, implementing new technologies can be challenging.  If you need help beyond the available documentation, the IBM i Technology Services team (formerly known as Lab Services) is available to help with implementation planning, execution, and knowledge transfer.  See https://www.ibm.com/it-infrastructure/services/lab-services for contact information or speak to your IBM Sales Representative or Business Partner.  If you are planning a new hardware purchase, you can include implementation services by the Technology Services team in your purchase.

Disclaimer

I am an employee of IBM on the IBM i Technology Services team (formerly known as Lab Services).  The opinions in this post are mine and don't necessarily represent IBM's positions, strategies, or opinions.

 

References:

2022 IBM i Marketplace Survey Results - Fortra

https://www.fortra.com/resources/guides/ibm-i-marketplace-survey-results

 

IBM i Virtualization Summary

https://www.ibm.com/support/pages/node/1135420

 

Introduction to SR-IOV and vNIC for IBM i

 

This is the first in a series of articles on frequently overlooked Power systems features that highlight the value for IBM i customers, starting with sharing Ethernet adapters with SR-IOV, and the added benefits that can be achieved with vNIC technology on top of SR-IOV. 

Whether you have an existing system that is already capable of these features, or you are considering migrating to new hardware, you can only benefit from knowing what your options are.

What Is SR-IOV?

SR-IOV (Single Root Input/Output Virtualization) is a hardware specification that allows multiple operating systems to simultaneously use a single I/O adapter in a virtualized environment.  It is not unique to the Power Hypervisor (PHYP).  You can find SR-IOV being used heavily in x86 based virtualization, such as VMWare or Hyper-V – a fact that just serves to complicate searches for information related to IBM i.

More to the point for the IBM i administrator, it allows a single SR-IOV capable adapter to be shared by multiple LPARs.  You can split a single adapter with two ports, dedicating each port to a separate lpar, or you can go more granular and share different percentages of the bandwidth of a single physical port between multiple partitions.  When sharing a single physical port, you get to specify the minimum percentage of outgoing bandwidth each partition gets, allowing each partition to use available bandwidth to burst higher when necessary.  It is also possible to limit the maximum outgoing bandwidth a given partition will use, although this is only possible via the HMC CLI, not the HMC GUI.

What is vNIC?

vNIC is a Power virtualization technology built into PowerVM that leverages the combination of VIOS (Virtual I/O Server) virtualization with SR-IOV adapters to get the performance and flexibility of SR-IOV with the additional flexibility and redundancy of a fully virtualized solution.  I expect to expand on VIOS in much more detail in future article.  For now, I’ll just say that vNIC provides an automated active/passive failover ability and supports the use of Live Partition Mobility.  If you already use VIOS, you should strongly consider SR-IOV adapters with vNIC rather than Shared Ethernet Adapters (SEA) unless you need the active/active load sharing configuration that is only available with SEA.  If you don’t use VIOS, watch out for a future article for why you should.

Why SR-IOV?

-          Better use of limited resources.  10G ethernet adapters have become common in enterprise configurations.  Most of these adapters have multiple ports.  Without SR-IOV, each adapter is usually dedicated to a single partition, often leaving the extra ports unused while additional adapters are dedicated to other partitions, leaving even more ports unused.  How many of these ports are utilized to their full capacity?  Not as many as you might think (seriously, collect some performance stats and see for yourself).  More adapters used at a fraction of their capacity means more cabling and more network switch ports, all used at a fraction of their capacity.  That gets costly, for both the server and network budgets, especially when working with 10G ports.

-          More flexibility.  Once you have connected ports to network switches, you can add partitions that use those ports without any additional cabling or network configuration.  This is especially true if you configure those ports as trunks and use VLAN tagging at the IBM i TCP/IP configuration to access different networks and IP address ranges.

-          Better Performance than other shared configurations.  Compared to traditional server-based networking configurations (VIOS Shared Ethernet Adapters or IBM i NWS Virtual Ethernet), SR-IOV connections perform much better.  Virtual ethernet connections have processor overhead, and many tuning parameters that limit performance.  SR-IOV establishes a hypervisor managed path to the hardware that is second only to a dedicated adapter.  In the real world, SR-IOV will perform effectively the same as a dedicated adapter, and better than any server virtualized adapter.

Who should use SR-IOV?

-          Large Enterprises should consider SR-IOV and vNIC technology to achieve high bandwidth connectivity to enterprise scale 10G (and up) infrastructure .  Automatic failover (vNIC) to redundant connections ensures connectivity that leverages the highly redundant network infrastructures that exist in high-end enterprises.

-          Small businesses should consider SR-IOV and vNIC technology to get the maximum capacity out of the investment in network connectivity.  Fewer adapters, less cabling and a smaller number of network ports is easier on the budget, while still providing the ability to adapt to changing business needs.  SR-IOV adapters provide the ability to share adapters between partitions without any server based virtualization, resulting in a simple to maintain shared configuration when other virtualization functions are not required.

What else do I need to know?

-          For all of the following, see the SR-IOV FAQ for details.  It can be found at:  https://community.ibm.com/community/user/power/viewdocument/sr-iov-vnic-and-hnv-information

  • You must have an SR-IOV supported adapter, so make sure your IBM Sales Representative or Business Partner knows you want SR-IOV when ordering a new system.
  • SR-IOV adapters must be placed in specific slots.  On Power 9 and Power 10 hardware, this includes most of the slots in the system.
  • There are limits on the number of SR-IOV enabled adapters per system.  As of November 2022, the maximum number of SR-IOV shared adapters is lower of 32 or the number of SR-IOV slots in the system.  This is not really limiting for most customers.
  • There are limits on how many shared (logical) ports can be assigned to a physical port, depending on the specific adapter (Ranging from 4 to 60)
  • There are limits on how many shared (logical) ports can be assigned per adapter (ranging from 48 to 120)
  • SR-IOV adapters in shared mode require Hypervisor memory (see FAQ)
  • Pay particular attention to limitations for 1G ports on supported adapters, especially 1G SFP+ in 10G+ adapters as these may not be supported for SR-IOV.
  • HMC is required for SR-IOV support.
  • VIOS is required for vNIC.  VIOS is NOT required for SR-IOV.
  • Sharing a Link Aggregation (e.g. LACP) of multiple ports is not allowed.  This is not as bad as it sounds as Link aggregation is effectively used as a redundancy measure in a VIOS SEA configuration rather than as a performance measure.  SEA simply does not have the capacity to use more than a single link’s bandwidth.  In practically all cases where Link Aggregation is used with VIOS, vNIC with failover is a better solution.  In the rare case that it is necessary, Link Aggregation can be managed at the IBM i O/S level with the CRTLINETH RSRCNAME(*AGG) command if the SR-IOV physical ports are 100% dedicated to a single partition.  See https://www.ibm.com/support/pages/configuring-ethernet-link-aggregation
  • Changing the minimum capacity of a SR-IOV logical port is disruptive, so plan accordingly.  Remember that the value is a minimum, and all logical ports can burst higher.  This means that barring any specific continuous outgoing bandwidth requirements, you are better off estimating low.
  • Bandwidth splitting on SR-IOV adapters is based on outgoing bandwidth only.  There is no way to split incoming bandwidth, so consideration should be given to anticipated incoming bandwidth when deciding on how many partitions can share a port.
  • SR-IOV cards are not owned by any partition, so typically adapter firmware updates are included in System firmware updates.  If necessary, there is a separate procedure to install adapter firmware updates separately that you may need to use. 

How to configure an SR-IOV port on IBM i

Rather than including a bunch of HMC screenshots that duplicate existing resources, I’ll direct you to the excellent reference material in the “Selected References” below, especially the Redpaper.  These references will show you how to put an SR-IOV adapter in shared or hypervisor mode and how to configure a logical port for a partition.  There is no difference between doing this for AIX and IBM i.  The specific web interface may change a bit with each HMC release, but the concepts remain the same.

Once the resource is created, the easiest way to determine the resource name is to select the partition from the HMC and get the CMNxx resource name from the “Hardware Virtualized I/O” page for SR-IOV, or the “vNIC” page for a vNIC.  It will also show up along with all of the other resources in WRKHDWRSC *CMN, or STRSST.  Once the resource name is located, configure it exactly as you would any other Ethernet resource by creating a Line description, IP address, etc.

You can dynamically add and remove SR-IOV and vNIC resources to/from a running partition.  Make sure that if you remove one, there are not any configurations using that resource.

What if you need help implementing SR-IOV or vNIC on an IBM i?

Whether you have a large environment or small, implementing new technologies can be challenging.  If you need help beyond the available documentation, the IBM i Technology Services team (formerly known as Lab Services) is available to help with implementation planning, execution, and knowledge transfer.  See https://www.ibm.com/it-infrastructure/services/lab-services for contact information or speak to your IBM Sales Representative or Business Partner.  If you are planning a new hardware purchase, you can include implementation services by the Technology Services team in your purchase.

Disclaimer

I am an employee of IBM on the IBM i Technology Services team (formerly known as Lab Services).  The opinions in this post are my own and don't necessarily represent IBM's positions, strategies, or opinions.

Selected References

I often find that researching topics related to Power Systems provides a wealth of information relating to AIX and VIOS, and substantially less that relates directly to IBM i.  Having spent a few years administering AIX systems, I am familiar with the many excellent AIX blogs that are available.  Many of these references are very AIX focused, but don’t let that dissuade you from reading them -- they are also excellent resources for IBM i administrators.

 

IBM Power Systems SR-IOV Technical Overview and Introduction Redpaper https://www.redbooks.ibm.com/abstracts/redp5065.html

 

IBM Support: Configuring Ethernet Link Aggregation

https://www.ibm.com/support/pages/configuring-ethernet-link-aggregation

 

IBM Community: SR-IOV FAQ

https://community.ibm.com/community/user/power/viewdocument/sr-iov-vnic-and-hnv-information

 

AIX for System Administrators – SR-IOV & vNIC summary pages

http://aix4admins.blogspot.com/2016/01/sr-iov-vnic.html

http://aix4admins.blogspot.com/2017/03/vnic_20.html

 

YouTube – This is the replay from the May 28th, Power Systems Virtual User Group Webinar covering Single Root I/O Virtualization (SR-IOV) presented by expert Chuck Graham

https://youtu.be/1ANyxQaSXOI


TL;DR 

SR-IOV lets you share ethernet adapter cards across multiple IBM i partitions without using VIOS.  vNIC adds the ability to include automatic active/passive failover if you also use VIOS.

 

Proactive vNIC Changes for VIOS Maintenance

In January 2023, I published an article and shared Python code that allows monitoring of your systems to verify your vNIC backing devices ar...